Dự báo EHDE: EC_0.25_SD (downscale từ 1.5°) so với EC_0.25 gốc (../HW ope1b)

Cùng hệ Ope1b, cùng bộ test 416 init của 4 năm kiểm định, cùng code chấm điểm (final_verify.py). Khác biệt DUY NHẤT: đầu vào EC ở 0.25° gốc hay downscale từ 1.5°. Mỗi ô: gốc | SD | Δ(SD−gốc). n_init SD=416.

Kỹ năng toàn quốc (national), W1–W6

tuầnPODPOFDFARFBICSISEDIEDI
gốcSDΔgốcSDΔgốcSDΔgốcSDΔgốcSDΔgốcSDΔgốcSDΔ
W10.6520.643-0.0100.1020.102-0.0000.1980.201+0.0020.8140.804-0.0100.5620.553-0.0090.7240.715-0.0090.6850.676-0.009
W20.5780.574-0.0040.2040.203-0.0000.4550.456+0.0021.0601.056-0.0050.3900.387-0.0030.5200.515-0.0050.4880.483-0.005
W30.4890.501+0.0130.2090.214+0.0050.5060.506-0.0010.9901.014+0.0240.3260.331+0.0060.4030.412+0.0090.3720.381+0.009
W40.4830.495+0.0120.2270.237+0.0100.5280.532+0.0051.0231.059+0.0360.3140.317+0.0030.3700.371+0.0010.3420.344+0.002
W50.4690.472+0.0030.2360.240+0.0040.5460.549+0.0021.0341.046+0.0120.3000.300+0.0000.3380.336-0.0020.3120.310-0.001
W60.4590.450-0.0100.2330.241+0.0080.5460.560+0.0141.0131.022+0.0090.2960.286-0.0100.3300.305-0.0250.3040.280-0.024

Chỉ tiêu nghiệp vụ tại W1 (hệ EC_0.25_SD)

Kết luận tải-0.25-hay-1.5 điền sau khi đọc bảng: nếu Δ nhỏ trên toàn W1–W6 thì 1.5°+downscale là đủ; nếu SD kém hẳn (đặc biệt W1) thì cần tải 0.25° gốc.